Wednesday, August 21, 2019

Causes of Luminescence and Chemiluminescence

Causes of Luminescence and Chemiluminescence 1.1. Luminescence Phenomena Luminescence is the phenomenon of emission of electromagnetic radiation in excess of thermal radiation. The radiation is usually in the visible region of the electromagnetic spectrum, however, since the same basic processes may yield infrared or ultra violet radiation. Luminescence is observed with all phases of matter: gases, liquids and solids both organic and inorganic[1]. Luminescence is an umbrella term for those kinds of events where light emission is not the result of high temperature. In fact with increasing temperature the competing nonradiative de – excitation processes become more probable and the intensity of the luminescent emission decreases. Luminescence in living organisms has been reported as far back as 1500 BC. In Chinese literature, the best known examples being the emission of light from fireflies and glow – worms[2, 3]. 1.1.1Types of Luminescence Classification according to the means by which energy is supplied to excite the luminescent molecule[4-8].Table 1.1 Table (1-1):- Different types of luminescence phenomena Excitation source Luminescence type Produced from irradiation Absorption of Uv-vis or near IR radiation. (Conversion of light energy to chemical energy). Photoluminescence Emission produced from irradiation of ÃŽ ² particles. Cathodoluminescence Emission produced from irradiation of ÃŽ ± particle. Anodoluminescence Radiation-induced chemical excitation (irradiation of ÃŽ ³ particles. Radiodoluminescence Produced from heating. Emission from incandescent solids Candoluminescence Caused by solid subjected to mild heating. Thermoluminescence Flame-excited metal atoms Pyroluminescence Produced from structural rearrangements in solids Emission from shaking, rubbing, or crushing crystals. Triboluminescence Emission from crystallization. Crystalloluminescence Excitation induced from dissolution of an irradiated or other energy-donating solid. Lyoluminescence Produced from electrical phenomena. Radiative recombination of electrons and holes in material (emission from electrical discharge) Electroluminescence Emission during electrolysis Galvanoluminescence Excitation of compounds by ultra-sonication. Sonoluminescence Emission from fractional charge separation at the crystal surface. Piezoluminescence Produced from chemical reactions Emission from luminous organisms. Bioluminescence Chemical excitation of compounds. Chemiluminescence 1.2. Chemiluminescence The term chemiluminescence (CL.) was first coined by Eilhardt Weidman in 1888. Chemiluminescence is defined as the production of electromagnetic radiation observed when a chemical reaction yields an electronically excited intermediate or product. CL-reactions emit light of varying degrees of intensity and lifetime. With colors that spare the visible spectrum [9-11]. Analytically, the CL-reactions are attractive due to: excellent detection limits results from the absence of source of noise and scattering, suitable to both batch and flow techniques highly sensitive, determinable over a wide range of concentrations, easy to operate, simplicity, absence of unwanted background so the only background signal is that of the PMT dark current and no excitation source or optical filters are required as compared to other optical or photo luminescence methods [12, 13]. However, some disadvantages are to be considered as well; A chemiluminescence reagent may yield significant emission not just for one unique analyte i.e. a lack of selectivity may occur. Moreover, chemiluminescence emission intensities are sensitive to a variety of environmental factors such as temperature, solvent, ionic strength, pH and other species present in the system. As a result, a separation condition (HPLC, capillary electrophoresis (CE), may not always match the optimum CL-emission conditions. Third, as the emission intensity from a CL-reaction varies with time,light flash composed of signal increase after reagent mixing, passing through a maximum, then decreasing back to the base – line, thus the CL- emission versus time profile differs from one compound to another and care has to be taken to detect the signal in the flowing stream during strictly defined periods [14].chemiluminescence technique is versatile for determination of a wide variety of species that can participate in the CL-reaction such as; CL-substrates or CL-precursors responsible for the excited state [15], the necessary reagent for the CL-reactions (usually an oxidant) [16] , some species that enhance the rate or sensitivity of the CL-reaction[17] ,activators such as catalysts (enzymes[18] or metal ions[19] CL. analysis found a wide application not only in the organic technology, medicine, food testing, but also in environmental monitoring and material science [20-24]. CL-reactions can be coupled as a detection technique [25] in chromatography [26, 27], capillary electrophoresis [28-30], or immunoassay, providing qualitative and / or quantitative information [31, 32]. 1.2.1. Mechanisms of Chemiluminescence Reaction Figure (1-2) shows the types of the CL-reaction mechanisms. In general CL-reactions can be generated by two basis mechanisms: Figure (1-2):- Types of CL-reactions. P, product; F, fluorescing substance Direct CL-reactions: a substrate (A) and an oxidant (B) in the presence of cofactors react to form an intermediate product in an electronically excited state which relaxes to the ground state with a photon emission. The catalyst is an enzyme or metal ions, reduces the activation energy and provides an adequate environment for producing high CL-efficiency out of the process.Cofactors sometimes are necessary to convert one or more of the substrates into a form capable of reacting and interacting with the catalyst,or to provide an efficient leaving group if bond cleavage is required to produce the excited emitter [33]. An alternative for compounds producing ultra-weak CL-emission is: Indirect or sensitized CL reactions: Since not all excited states of CL-reactions products are effective â€Å"emitters† in any case, thus the excited state energy can be transferred to an â€Å" effective â€Å" flourophore added to the system, in –order to increase the CL-intensity substantially . The most salient asset of chemical excitation is the low background noise involved, which results in very low detection limits (in the sub femtomole of region) [34,35]. Enhanced CL- reactions (ECL): describes the phenomenon which has been observed in a wide range of chemi and bioluminescence reactions. Enhancement of light emission from the luminol-hydrogen peroxide reaction at alkaline pH has been achieved by the addition of various organic compounds generally containing oxonium group. Enhancement of CL. Reaction led to intense light emission, prolonged light emission and low background[36]. Spontaneous light emission during reaction requires the presence of the following conditions[37]: The reaction must be highly exothermic (40-70 kcal/mole) in order that the CL-reaction occurred in the visible region (400 nm (violet) – 750nm (red). These exothermic conditions associated with redox reactions using Oxygen, Ozone andhydrogen peroxide or similar potential oxidants. The reaction pathway must be a favorable to channel the energy for the formation of an electronically excited state. Photon emission must be favorable deactivation process of the excited product in relation to other competitive non-radiative processes that may appear in low proportion. There are several ways for an electronically excited state species to lose its extra energy, either by reacting with another molecule, molecular dissociation, and collision with its surrounding molecules or luminescence. In the latter case it can react to liberate sufficient energy to produce photon of visible light, figure (1-3). Figure (1-3):-possible de-excitation pathways of excited molecule 1.2.2. Main Chemiluminescence-systems for analytical processes 1.2.2.1. Gas- phase chemiluminescence reactions. The development of Chemiluminescence Methods for determining components of a gas is largely originated from the need to determine atmospheric pollutants such as Ozone, Oxides of nitrogen and sulfur compounds[45, 46].The best known and most frequently used is the reaction of nitrogen oxide withOzone.CL-NOXanalyzers have been shown to respond to a number of nitrogenous pollutants besides NO and NO2. [40].Some analytical methods based on CL- reactions have been proposed for the determination of sulfur monoxide and unsaturated hydrocarbons such as Alkenes, alkynes and aromatics at high temperature,several of these are as follows[41-44]. NO+ O3NO2* + O2NO2 + hÃŽ ½(600-2800 nm)(1) (2) (3) Oxygen atoms also been applied as strong oxidants when reacted with a wide range of analyst, although not so frequently used. The reaction with nitric oxide produces a yellow- green CL-emission that has been used for measuring concentration of Oxygen atoms in kinetics experiments[45]. (4) Some CL. Reactions are based on the light emission produced in flame, rather than the cold CL-emission. Molecular emission cavity analysis (MECA) is a CL-technique in which molecular emission are generated within a cavity that is introduced into a hydrogen diffusion flame. This flame acts as the environments of radicals, atoms and molecules which promote the chemical reactions (i.e. high temperature of flame promote of chemical reactions that form key reaction intermediates and provide additional thermal excitation of the emitting species).The cavity acts as the environment for stabilizing the emitting species. MECA has been used for selective detection of compounds containing sulfur, nitrogen, phosphorous, antimony, arsenic,.Tin and halogens [46-54]. 1.2.2.2. Liquid- phase chemiluminescence reactions There are some well – established CL-reagents that have been used for solution – phase CL-reactions, their attraction include high sensitivity, wide dynamic range and simplicity [55].The Chemiluminescence of luminal and the cyclic hydrazides of aromatic and heterocyclic acids is one of the classical and still studied in CL-reactions [56]. Although hydrazides in general are Chemiluminescent, onlyhydrazides related to luminol (5 – aminophthalyhydrazide) can be considered the most commonly used. The CL. of luminol was first described by Albrecht in 1928. This compound reacts with potent oxidizing agents in the presence of catalyst in alkaline medium to yield 3 – amino phthalate in an excited electronic state which returned to the ground state; with the production ofblue emission at 425 nm.The reaction is catalyzed by metal ions.Alternatively, it has been proposed that the metal ion forms a complex with the hydrazide which is then oxidized[57–59]. Lophin(2,4,5 – triphenylimidazole) is the most representative of the imidazole CL-precursors . A yellow CL-emission is produced at 525 nm. by oxidation of Luphin in aqueous alkaline mediums[60]. Lucigenine(10, 10 dimethyl – 9, 9 -biascridiniumnitrate) is one of the most efficient CL-substances which emit an intense green emission at 470 nm. When oxidized in an alkaline medium [61]. In relation to indirect CL., one of the more efficient non – biological system that are used is based on and so – called peroxy oxalate CL-reaction (PO – CL ) which involves the hydrogen peroxide oxidation of an aryl oxalate ester in the presence of a fluorophore .Bis–( 2,4,6 – trichloro phenyl )oxalate (TCPO) and bis – ( 2,4– dinitro phenyl ) oxalate (DNPO ) are commonly used oxalates. These compounds are insoluble in water which requires the use of organic solvents such as acetonitrilies ,dioxane and ethyl acetate [62]. Another CL-system frequently applied involves the use of Ru [bpy]3+2 which produces an orange emission at 610 nm.From the excited state (Ru [bpy]3+2)* that can be obtained by different reactions which imply electron transfer and regeneration of Ru[bpy ]3+2 species. Recently , the higher CL-emission generated by a similar complex , Ru[phen]3+2(phen = 1,10 – phenanthroline) during oxidation ofRu [bpy ]3+2 by Ce(IV) in sulfuric acid medium Ru [bpy]3+2 is the most studied as an inorganic compound used in electro generated CL (ECL)[60,63]. 1.2.2.3.Solid Phase Chemiluminescence [35]. Some polymers exhibit weak CL. in the visible range when heated up in the presence of inert gas (air or oxygen). For the first time this phenomenon was observed by Ashby in 1961, from polypropylene. Emission of light during oxidation of polymers is called oxy- luminescence or oxychemiluminescence. And for CL. of polymers to be observed, oxygen must be present in the process. 1.2.3.Electro Generated Chemiluminescence (ECL) ECL : is the process in accordance with which , species generated at electrodes undergo high – energy electron – transfer reactions to form excited states that emit light , it occurs in the visible region of spectrum as a consequence of fast and highly exo-energetic electron . Transfer between a strong electron donor and electronacceptor which in turn results in generation of excited states [7].In general, electrically generated reactants diffuse from one or more electrodes, and undergo high – energy electron transfer reactions either with one other or with chemicals in solution. This process yields excited state molecules, which produce a CL- emission in the vicinity of the electrode surface. Application of ECL have almost exclusively focused on the reaction of tris(2, 2 – bipyridire) ruthenium Ru[bpy]3+2 the reaction takes place at room temperature . Wide pH range and in the presence of oxygen and many other impurities[64].Ru [bpy]3+2 itself can undergo electron transfer reactions to produce ECL as follows [65]. Luminol can undergo an ECL reaction due to its versatility in analytical determinations. in alkaline solution luminol anion undergoes a single electron electro-oxidation to form diazaquinine , which is further oxidized by peroxide or super oxide to give 3 – amino phthalate in an excited state , which emits light at 425 nm . Luminol ECL has been used for determination of species such as phenyl alanine, ibuprofen and hisidine [9]. 1.3. Fluorescence Photoluminescence becomes visible as optical radiation accompanied by the emission of photon depending on the duration of the phenomenon, i.e. life time of the excited state. Fluorescence is the spontaneous emission of light during transition of the system from its lowest vibrational energy level of an excited singlet state S1 back to the ground state S0,thus it’s a spin allowed process. Absorption and fluorescence don’t require any spin reorientation however; intersystem crossing and phosphorescence require a spin reorientation therefore; absorbance and fluorescence are much faster than phosphorescence. The processes that occur between the absorption and emission of light are usually illustrated by Jobalonski diagram [66, 67]; figure (1-4). Figure (1-4):- Perrin- Jobalonski diagram and illustration of the relative positions of absorption (Abs), fluorescence (F), andphosphorescence (Ph.) Fluorescence is the result of three stages process that occurs in certain molecules called fluorophores [67]. Excitation: a photon is supplied by an external source and absorbed by the fluorophore creating an excited electronic singlet state S1. This stage distinguishes fluorescence from chemiluminescence, in which the excited state is populated by a chemical reaction. State life time:fluorescence life time is typically 1-10 Nano sec. during this time the fluorophore undergoes conformational changes and is also subjected to a multitude of possible interactions with its molecular environment such as collisional quenching and intersystem crossing. Fluorescence emission: when a photon of energy is emitted returning the fluorophore to the ground stat S0. Figure (1-5) shows these three stages. Figure (1-5):- three stages of fluorescence emission process 1.3.1. Characteristics of fluorescence emission [68-70] Emission spectra are typically independent of the excitation wave length due to the partial dissipation of excitation energy during the excited state life time, this known as Kasha’s rule. The emission intensity is proportional to the amplitude of the fluorescence excitation spectrum at the excitation wavelength; figure (1-6). Figure (1-6):- emission spectra are typically independent of the excitation wavelength Stokes shift: due to the energy dissipation during the excited state life time, the energy of this photon is lower and therefore; of longer wavelength than the excitation photon (i.e.fluorescence light is a red-shift). This difference in energy or wavelength is known as stokes shift.† The difference in wavelength between positions of the band maxima of the absorption and emission spectra of the same electronic transition; figure (1-7). Solvent effects and excited state reactions can also affect the magnitude of stokes shift. Figure (1-7):-stokes shift of band maxima E = hÃŽ ½ = hÃâ€"c / ÃŽ » (1) h = Planck constant = 6.63 Ãâ€" 10-34 J.sec-1 c = light velocity ÃŽ ½ = light frequency Sec-1 or Hz ÃŽ » = wave length nm. Absorption energy EAbs.= hÃâ€"c / ÃŽ »Abs. (2) Emission energy Eem.= hÃâ€"c / ÃŽ »em. (3) Since: EemAbs. (4)so: ÃŽ »em.>ÃŽ »Abs (5) ÃŽ »em.,ÃŽ »Abs: emission and absorption spectra peaks respectively. When absorption and/or the emission spectra of a flourophore possess two or more bands, stokes shift is equal to the difference that separates the two most intense bands of the two spectra, figure (1-8). Figure (1-8):-stokes shift in a flourophore possess two bands If thermal energy is added to an excited state or compound has many highly populated vibrational energy levels, emission at shorter wavelengths than those of absorption occurs, this is called an anti-stokes shift and its often observed in dilute gasses at high temperatures. A key feature of fluorescence is the molecule spends a measurable Amount of time in the singlet state. Fluorescence life time refers to the average time that the molecule stays in its excited state before emitting a photon for fluorescence; it’s typically in the range (1-10 nsec.). Fluorescence radiant power (F) is proportional to the absorbed radiant power. F = É ¸ (P0 – P) - (6) É ¸: Fluorescence efficiency. P0: incident power. P: transmitted power. The relationship between the absorbed radiant power and concentration can be obtained from beers law P/P0 = 10-A- (7) P = P0 Ãâ€" 10-Ɇºbc - (8)F = É ¸ P0 (1–10-Ɇºbc)- (9) Structural factors. Fluorescence is expected in molecules that are aromatic or multiple conjugated double bonds with a high degree of resonance stability, it’s also expected with poly cyclic aromatic

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.